WARNING:
JavaScript is turned OFF. None of the links on this concept map will
work until it is reactivated.
If you need help turning JavaScript On, click here.
This Concept Map, created with IHMC CmapTools, has information related to: Node_20_Procedure to run up the Distiller, Procedures to follow To Run up Distiller, Follow By Distiller Steps For, 8] Open the Distillate Water Tank feed valve 9 ]Open the Air Ejector Valve 10] Open the De-Superheater Steam inlet and outlet valves 11] Start the Distillate Pump Distilled Should Flow to the Distilled Water Tank is indicated, Distiller Main Distrib Follow By, Distiller Main Distrib 1] Close the Evaporator SW Pump Breaker 2] Close the Distillate pump Breaker, 6] Open the Distiller SW feed inlet and outlet valves 7] Open the Distillate pump inlet and outlet valves Finally 8] Open the Distillate Water Tank feed valve 9 ]Open the Air Ejector Valve 10] Open the De-Superheater Steam inlet and outlet valves 11] Start the Distillate Pump, 3] Open the SW suction to SW Feed pump Valve 4] Open both inlet and outlet SW Feed Pump valves 5] Start the SW Feed Pump For Inlet and Outlet Valve 6] Open the Distiller SW feed inlet and outlet valves 7] Open the Distillate pump inlet and outlet valves, Steps For Feed Pumps 3] Open the SW suction to SW Feed pump Valve 4] Open both inlet and outlet SW Feed Pump valves 5] Start the SW Feed Pump