WARNING:
JavaScript is turned OFF. None of the links on this concept map will
work until it is reactivated.
If you need help turning JavaScript On, click here.
This Concept Map, created with IHMC CmapTools, has information related to: 6_101_Starting_Steam_Plant_From_DeadshipConditions, With availability of steam, Steam-Air heater should bestarted combustion rate is defined in graph below, Fill up boiler from distilled water tank ready for firing with correct water level Main Boiler, Main Boiler needs prior starting of 1) Forced-draft fan 2) Seal-air fan 3) Diesel oil system 4) Aux feed pump, Start Emergency Genset power up Emergency Switchboard, Start firing on Diesel oil after adequate purging Main Boiler, Start firing on Diesel oil combustion rate is defined in graph below, to Start 1) Air compressor for D/G starting 2) D/G D.O. Service pump 3) Control/ Service air compressors 4) D/G L.O. priming pump 5) Main cooling S.W. pump 6) Central cooling F.W. pump start Diesel Genset, Starting Steam Plant from Deadship Conditions - Starting of Boiler Need to Fill up boiler from distilled water tank, Main Switchboard Breakers switched on for 1) Forced-draft fan 2) Seal-air fan 3) Diesel oil system 4) Aux feed pump, Diesel Genset feeds Main Switchboard, Emergency Switchboard use power feedback to energize Main Switchboard, Starting Steam Plant from Deadship Conditions - Starting of Boiler Need to Start Emergency Genset