WARNING:
JavaScript is turned OFF. None of the links on this concept map will
work until it is reactivated.
If you need help turning JavaScript On, click here.
This Concept Map, created with IHMC CmapTools, has information related to: Node_14a_Precheck to Parallel the Turbo Alternator, Electrical Power Emergency Generator Auto, Stand-by, Before Paralleling the Turbo Alternator Ensure Boilers, Boilers Boiler 1 Pressure, Turbo Alternator is running without excessive vibrations, Electrical Power Turbo Generator 1 On, Electrical Power Shore Power Off, Before Paralleling the Turbo Alternator Ensure Deaerator, Before Paralleling the Turbo Alternator Ensure Turbo Alternator, Deaerator Full with guage glass reading Between 60~70 mm, Electrical Power Diesel Generator On, Condenser Condenser Vacuum Satisfactory and Cooling ON, Before Paralleling the Turbo Alternator Ensure Power, Boilers Boiler 2 Pressure, Tanks Atmospheric Drain Tank (ADT) About 60% full, Turbo Alternator is running without excessive noise, Before Paralleling the Turbo Alternator Ensure Tanks, Turbo Alternator is running without any other abnormality, Tanks Distilled Water Tank (DWT) About 60% full, Before Paralleling the Turbo Alternator Ensure Condenser, Pressure About 6 Mpa Running on HFO supply