LNG Steam Simulator Exercise
002. Run the Simulator to Fill both Boilers
[Load Snapshot "Ex_002_Procedure for filling Boilers" in the Simulator]
- Asssume scenario as described below [but check to confirm] and then follow the given procedures
Electrical Power:-
Shore Power:Off; Emergency Generator:Auto Stand-by; Both Turbo Generators:Off; Diesel Generator:On
Fuel Bunkers:-
All bunker tanks are full; Fuel oil settling tanks are full as well (both for diesel oil & heavy fuel oil).
Water Bunkers:-
All water bunker tanks are full.
Both Boilers:-
Empty
Control Air System:-
On - And valves open to all services.
Distilled Water Tank (DWT):-
Full (If not full to fill up deaerator at least 30%, DWT must be filled from the distiller or shore supply).
Deaerating Feed Tank (DFT):-
Full
>> Procedures for Filling Up both Boilers:-
Emerg Distrib:
1 Close the Emergency Feed Pump circuit breaker
T/bines and Feed:
2 Open the Emergency Feed Pump Suction and Discharge Valves
Port/Stbd Boiler:
[It is recommended that one boiler is filled first (before the second) so that water level may be monitored.]
3 Open Auxiliary Feed Stop Valve.
4 Open Auxiliary Feed Valve about 50%
5 Open Boiler Air Vent Valve
T/bines and Feed:
6 Start the Emergency Feed Pump
Port / Stbd Boiler:
7 Allow the boiler to fill to a level of approximately -4 inches (-100mm) then close a valve on the Auxiliary Feed line.
T/bines and feed:
8 Stop the Emergency Feed Pump